Who We Serve

Industrial Facilities

Geothermal and process HVAC at 500 FPM, long pad life, stable performance, low static pressure penalty.

Industrial Facilities

Why ECOairflow fits here

Industrial and geothermal HVAC pushes face velocities high and runs filters hard. The Model 2300 2″ was engineered for this regime, pad sets designed to last almost indefinitely, predictable pressure-drop curves measured at Blue Heaven Technologies, and the same UL2998 Zero Ozone certification that applies to the rest of the line.

  • Designed and tested at 500 FPM face velocity
  • Long pad life, pads designed to last almost indefinitely under stable loads
  • Custom cabinet sizes for non-standard air-handler footprints
  • Tandem-linkable; OEM/private-label available for cabinet builders
Recommended filters

What we typically spec for industrial facilities

Each of these is built around the same patented EPF core, they differ in cabinet depth, MERV target and pad geometry.

  • Model 2300 2″ (commercial & geothermal applications)
Where it goes

Typical applications in this building type

Industrial air handlers move the largest volumes on this list, which is exactly where a sustained low pressure drop compounds into the largest energy difference.

Production & process areas

High-volume make-up air and recirculation units where filter loading directly drives fan power.

Warehousing & logistics space

Large open volumes on long run hours, where a slow-loading filter extends the service interval.

Plant offices & control rooms

Occupied zones inside an industrial envelope that need a different air quality standard from the floor.

Mechanical & equipment rooms

Rooftop and in-plant units where a permanent aluminum frame survives handling far better than a pleated cartridge.

What changes

Where the operating economics change at industrial scale.

Fan energy stays flat

Open glass-fibre mesh loads far more slowly than pleated media, so static pressure, and the fan power that follows it, stays low across the whole service interval instead of climbing week over week.

One consumable, not a whole filter

The aluminum frame is permanent. Only the media pad is replaced, which changes what maintenance orders, stores and disposes of.

Certified for occupied space

ETL Listed, UL2998 Zero Ozone, UL867 and CSA, zero ozone and zero formaldehyde in service.

Sized to the cabinet you have

All standard sizes plus custom sizes built to order, so the unit fits the air handler already installed.

Common questions

Specifying Industrial Facilities

The questions we are asked most often when this building type is being specified.

Fan power scales with the cube of fan speed, so a small reduction in static pressure produces a disproportionately large reduction in fan energy. The larger the air volume, the larger that difference becomes.
Only the media pad. The aluminum frame is a one-time capital cost and stays in the unit, so a change-out is a single pad rather than a complete filter.
24V at approximately 2 watts per unit, a negligible electrical load against the fan energy it saves.
Spec it

Send us the building. We'll send back the unit.

One business-day reply, engineering review included.