ASHRAE 241 Standards for Infectious Aerosol Control
ECOairflow's ASHRAE 241 Standards for Infectious Aerosol Control product line features advanced electronic air cleaners engineered to meet and exceed the 2023 ASHRAE 241 infection-control filtration requirements. Utilizing patented Electronic Polarization Technology, these filters capture airborne pathogens, viruses, and ultrafine particles down to 0.001 microns while delivering significant energy savings over traditional filter systems.
Need help finding the right product?
Talk to our product experts for custom solutions.
Our Range of Products
Apply Filters
0.09
0.18
M-Series™ 2" Hybrid E.A.C. — Model 2300 M-Series Hospital-Grade Air Filter (MERV 14A / 16A, ASHRAE 170, Appendix J Certified)
MERV 14A/16A rated powered & unpowered
54% fan energy reduction vs. MERV 8+14 train
74.73% PM0.1 capture — beats HEPA by 50%
Dynamo™ 2" E.A.C. — Model 2300 Commercial Electronic Air Cleaner (MERV 14, 50% More Effective than HEPA at PM0.1)
MERV 14 powered; ASHRAE 241 compliant
74.73% PM0.1 capture, 50% better than HEPA
0.13 in.w.c. drop saves 54% fan energy
Dynamo™ 1" E.A.C. — Premium Whole-Home Electronic Air Cleaner for Residential HVAC (MERV 12, Lifetime Electronics Warranty, 2x More Effective than HEPA at Ultra-Fine Particles)
MERV 12; captures particles to 0.001 microns
2x more effective than HEPA at PM0.1 range
Lifetime electronics warranty to original owner
Model 1500 — Whole-Home Electronic Air Cleaner for Residential HVAC (MERV 12, Captures Particles Down to 0.007 Microns)
MERV 12; captures down to 0.007 microns
9% larger capture area, lower pressure drop
Saves up to 15% yearly on HVAC energy costs
Model 1000 — Affordable Whole-Home Electronic Air Cleaner for Residential HVAC (MERV 11, Captures Down to 0.001 Microns)
MERV 11; captures particles to 0.001 microns
UL 2998 zero-ozone certified, ETL verified
Tool-free pad swap, 5-year full warranty
Frequently Asked Questions
What is the ASHRAE 241 compliance?
ASHRAE 241 (2023) is the Standard for Infection Aerosol Control that establishes minimum requirements for HVAC filtration and ventilation systems to reduce the risk of infectious aerosol transmission in buildings. Compliance requires filtration at MERV 13 or higher. ECOairflow's M-Series and Dynamo 2" filters meet and exceed this standard, providing verified pathogen capture for healthcare and commercial facilities.
What is the ASHRAE 241 test?
The ASHRAE 241 test evaluates a building's equivalent clean air delivery rate (EADR), measuring how effectively the HVAC system reduces infectious aerosol concentrations. Filters must achieve MERV 13 or higher under ASHRAE 52.2 test protocols, including Appendix J conditioning for electronic air cleaners. ECOairflow's M-Series filters are Appendix J certified at MERV 13-A through 16-A, confirming consistent in-situ performance across the full filter lifecycle.
Which ECOairflow products comply with ASHRAE 241?
The M-Series 2" Hybrid E.A.C. (Model 2300 M-Series) and the Dynamo 2" E.A.C. (Model 2300) both comply with ASHRAE 241 (2023). The M-Series achieves MERV 14A or 16A under Appendix J certification, and the Dynamo 2" exceeds the ASHRAE 241 minimum at MERV 14 powered. Both filters capture particles down to 0.001 microns, covering the critical size range for airborne infectious aerosols.
How does ASHRAE 241 relate to ASHRAE 170 for hospitals?
ASHRAE 170 governs ventilation and filtration in healthcare facilities, specifying MERV 14 for emergency and treatment rooms and MERV 16 for operating rooms. ASHRAE 241 applies infection-control filtration requirements to all occupied building types. ECOairflow's M-Series satisfies both standards simultaneously — ASHRAE 170 MERV 14A or 16A for clinical spaces and ASHRAE 241 infection-control requirements — using a single 2" hybrid filter pad.
Can ASHRAE 241 compliant filters reduce energy costs?
Yes. ECOairflow's ASHRAE 241 compliant filters feature extremely low pressure drops (0.13–0.37 in.w.c.) compared to traditional MERV 8 + MERV 14 bag filter trains (0.6–1.2 in.w.g.). An independent hospital study documented a 54% reduction in fan power consumption over 12 weeks, demonstrating that facilities can achieve ASHRAE 241 infection-control compliance without the significant energy penalty typical of high-MERV conventional filtration systems.
Do ECOairflow filters maintain MERV performance during a power outage?
Yes — the M-Series Hybrid E.A.C. maintains its full rated MERV performance whether powered, unpowered, or conditioned under ASHRAE 52.2 Appendix J protocol. This is a unique and critical capability for medical treatment rooms and healthcare environments where filter performance must be assured even during power loss or scheduled shutdowns, ensuring continuous infection-aerosol control under all operating conditions.
What documentation is available for specifying engineers and procurement?
ECOairflow provides comprehensive submittal documentation including ASHRAE 241 and ASHRAE 170 compliance documentation, ASHRAE 52.2 Appendix J certification data, PM0.1 independent lab-test reports, UL 2998 Zero Ozone verification, LEED EQ credit documentation, and CSA Z317.2 compliance data. All documents are available on request by contacting sales@ecoairflow.com or calling 1-877-347-3569.
Didn't find what you're looking for?
Talk to our experts for custom solutions and tailored guidance.
Industries We Serve
Hospitals & Healthcare Facilities
Provides ASHRAE 170 and 241 compliant MERV 14A–16A filtration for ORs, ICUs, treatment rooms, and protective environments.
Commercial Office Buildings
Delivers ASHRAE 241 infection-control filtration and LEED EQ credits with low pressure drop for energy-efficient commercial HVAC systems.
Schools & Universities
Reduces infectious aerosol risk in classrooms, nurse stations, and athletic facilities while supporting ASHRAE 241 compliance and energy savings.
Government & Federal Buildings
Meets GSA and ASHRAE 241 infection-control filtration requirements for federal facilities, VA hospitals, and government procurement projects.
Didn't find what you're looking for?
Talk to our experts for custom solutions and tailored guidance.
Our M-Series and Dynamo 2" filters meet and exceed ASHRAE 241 (2023) infection-control filtration requirements, capturing airborne pathogens and viruses down to 0.001 microns for verified occupant safety.
54% Fan Energy Reduction Documented
Independent hospital studies confirm a 54% reduction in fan power consumption over 12 weeks versus traditional MERV 8 + MERV 14 bag filter trains, delivering compliance without the typical energy penalty.
Appendix J Certified Consistent Performance
ECOairflow filters maintain full rated MERV performance whether powered, unpowered, or under ASHRAE 52.2 Appendix J conditioning, ensuring clinical safety and filtration reliability throughout the entire lifecycle.
Specify ASHRAE 241 Compliant Filtration for Your Facility
Submit your project details and our team will provide submittal documentation, ASHRAE compliance data, and pricing within one business day.